fireclass

MAD-565-I

Addressable loop sounder with VAD EN54-23

Description

  • Addressable loop sounder and white flash with built-in isolator. 32 tones and 2 configurable volumes (Low, High). Acoustic power from 95 dBA to 100 dBA, depending on the selected tone. It takes just one address in the loop. Red color. IP65. High base for visible tube entry. CPR certificate EN 54-3, EN 54-23 and EN 54-17.VAD Coverage of W-4-9 and W-3-7. Powered from the loop or from an external power supply (24Vcc). Dimensions: 63 x 118 x 121 mm.
  • fireclass

    MAD-565-I-W

    Addressable loop sounder with VAD EN54-23 (white color)

    Description

  • Addressable loop sounder and white flash with built-in isolator. 32 tones and 2 configurable volumes (Low, High). Acoustic power from 95 dBA to 100 dBA, depending on the selected tone. It takes just one address in the loop. Red color. IP65. High base for visible tube entry. CPR certificate EN 54-3, EN 54-23 and EN 54-17.VAD Coverage of W-4-9 and W-3-7. Powered from the loop or from an external power supply (24Vcc). Dimensions: 63 x 118 x 121 mm.
  • fireclass

    MAD-564-I

    Addressable loop sounder with built-in isolator

    Description

  • Addressable loop sounder with built-in isolator for direct connection to the loop. 32 tones and configurable volumes (Low, High). Acoustic power from 95 dBA to 100 dBA, depending on the selected tone. It takes just one address in the loop. Red color. IP65. High base for visible tube entry. CPR certificate EN 54-3 and EN 54-17. Powered from the loop or from an external power supply (24Vcc). Dimensions: 63 x 118 x 121 mm.
  • fireclass

    MAD-564-I-W

    Addressable loop sounder with built-in isolator (white color)

    Description

  • Addressable loop sounder with built-in isolator for direct connection to the loop. 32 tones and configurable volumes (Low, High). Acoustic power from 95 dBA to 100 dBA, depending on the selected tone. It takes just one address in the loop. White color. IP65. High base for visible tube entry. CPR certificate EN 54-3 and EN 54-17. Powered from the loop or from an external power supply (24Vcc). Dimensions: 63 x 118 x 121 mm.
  • fireclass

    MAD-461-I

    Addressable loop sounder with isolator and low power consumption

    Description

  • Addressable loop sounder with isolator. Low power consumption, acoustic power 82.5 dB. It takes just one address in the loop. Color red. For indoor use. IP21. CPR certificate EN54-3 and EN54-17. Dimensions: 65 x 90 mm.
  • fireclass

    MAD-464-I

    Addressable loop sounder with built-in isolator

    Description

  • Addressable loop sounder with built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power from 78.3 dBA to 104.6 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
  • fireclass

    MAD-465-I

    Addressable loop sounder with beacon and built-in isolator

    Description

  • Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
  • fireclass

    MAD-464-I-W

    Addressable loop sounder with built-in isolator (white color)

    Description

  • Addressable loop sounder with built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power from 78.3 dBA to 104.6 dBA depending on the selected tone. It takes just one address in the loop. White color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
  • fireclass

    MAD-465-I-W

    Addressable loop sounder with beacon and built-in isolator (white color)

    Description

  • Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. White color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
  • fireclass

    MAD-472

    Addressable sounder base

    Description

  • Addressable sounder base. 200A series detector compatible. CPR Certified EN54-3. Acoustic power: 80dB. Indoor use. IP21C. Dimensions: 150 x 100 mm.
  • fireclass

    MAD-473

    Addressable sounder base with beacon

    Description

  • Addressable sounder base with beacon. 200A series detector compatible. CPR Certified EN54-3. Acoustic power: 80dB. Indoor use. IP21C. Dimensions: 150 x 100 mm.
  • fireclass

    MAD-470

    Protective cap for the MAD-472 and MAD-473 sounder bases

    Description

  • Protective cap for the MAD-472 and MAD-473 sounder bases.