FireProtect 2 (Heat/Smoke/CO) Jeweller
Wireless fire detector with heat, smoke, and CO sensors
Product versions
FireProtect 2 RB (Heat/Smoke/CO) Jeweller
Up to 7 years of operation on replaceable batteries
FireProtect 2 SB (Heat/Smoke/CO) Jeweller
Up to 10 years of operation on sealed batteries
Accuracy through steam, dust, and time
FireProtect 2 (Heat/Smoke/CO) Jeweller is a battery-powered fire detector designed to protect homes without false alarms. Its dustproof and insect-resistant smoke chamber, dual-spectrum optical sensor, proprietary software algorithm, two thermistors, and a chemical carbon monoxide (CO) sensor deliver best-in-class detection accuracy. If danger is real, an 85 dB siren, two interconnection types, and instant push notifications in Ajax apps make the alarm impossible to ignore. With thoughtful design, self-monitoring, and early low battery alerts, the device ensures uninterrupted protection with fewer maintenance visits.
Key features
Awards
Wherever there is a risk of fire
Discover future-proof hardware
Detection without compromise
Smoke detection
The detector is designed to ensure accurate smoke detection over time. A dustproof and insect-resistant smoke chamber features a dual-spectrum optical sensor. It uses blue and infrared LEDs to measure the concentration of combustion products and the size of their volatile particles. The HazeFlow 2 algorithm then analyzes the collected data to distinguish smoke from false triggers, such as vapor or steam. If the analysis indicates a real fire, the detector instantly raises an alarm.
Heat detection
FireProtect 2 (Heat/Smoke/CO) Jeweller is equipped with two A1R-class thermistors to detect smokeless fires. Positioned outside the enclosure, the thermistors immediately register if the temperature rises by 10 °C within a minute or exceeds a threshold of +64 °C. This design ensures the fastest possible response, even when a threat grows gradually.
CO detection
CO is a highly poisonous yet colorless and odorless gas. Without a CO detector, it can build up unnoticed until poisoning occurs. Equipped with a chemical sensor, FireProtect 2 (Heat/Smoke/CO) Jeweller monitors the CO level and warns about dangerous concentrations before the first symptoms appear. The sensor ensures reliable CO detection for up to 10 years.
The detector is triggered if the CO level reaches:
- 50 ppm in no more than 90 minutes
- 100 ppm in no more than 40 minutes
- 300 ppm in no more than 3 minutes
Stable performance for a decade
FireProtect 2 (Heat/Smoke/CO) Jeweller delivers up to 10 years of autonomous operation thanks to pre-installed batteries, sealed or replaceable. Real-time battery status is always visible in Ajax apps, so there is no need for unnecessary maintenance visits. If the battery runs low, users receive push notifications and on-site LED and sound alerts 30 days before the full discharge.
SB version
Up to 10 years of operation
on sealed batteries
RB version
Up to 7 years of operation
on replaceable CR123A batteries
Clear alerts for faster response
In addition to LED indication, FireProtect 2 (Heat/Smoke/CO) Jeweller features impossible-to-ignore sound alerts, thanks to a powerful 85 dB siren with distinct tones. Each indication corresponds to a specific event, drawing attention and helping users react accordingly.
Sound and LED indications
Smoke or heat alarms
Dangerous CO level
Malfunction
Low battery
End of life
Enhanced wireless interconnection
To spread an alarm across the facility as quickly as possible, FireProtect 2 (Heat/Smoke/CO) Jeweller supports primary and fallback1 interconnection with other on-site fire detectors. The primary one operates via a hub: the detectors alert the hub to a threat, which then activates the sirens of all fire detectors on-site. The process takes just 20 seconds — three times faster than standards require. If hub communication is lost, the fallback interconnection takes over. The initiating fire detector directly communicates with other devices, raising the alarm across the system within a minute. Even in the worst-case scenario, people on-site are warned and have time to act.
20 seconds to activate up to 200 fire detectors
60 seconds to activate up to 50 fire detectors
Advanced automation for greater safety
While FireProtect 2 Jeweller detectors can be used as standalone devices, they gain many more capabilities within a larger Ajax system. They can interact with automation devices and MotionCam (PhOD) Jeweller detectors via scenarios, triggering automated responses to fire alarms. This interaction helps enhance home protection when people are away or speed up evacuation when they are on site.
To quickly assess the situation at the protected facility and respond accordingly.
Fire detected
FireProtect 2 Jeweller
MotionCam (PhOD) Jeweller
Cause of fire
To cut off power to a possible source of fire and protect appliances from the consequences of firefighting.
Fire detected
FireProtect 2 Jeweller
WallSwitch Jeweller
Mains power cut
Relay Jeweller
Emergency lights activated
To supply fresh air and reduce carbon monoxide concentration in the air.
CO detected
FireProtect 2 Jeweller
WallSwitch Jeweller
Ventilation on
To speed up people's evacuation and ease firefighters' access to the building.
Fire detected
FireProtect 2 Jeweller
Relay Jeweller
Emergency exits unlocked
Unique wireless technology
Jeweller is Ajax’s proprietary radio protocol for secure two-way communication. It provides block encryption and device authentication during each communication session with an Ajax hub or radio signal range extender. Jeweller prevents sabotage, spoofing, and data theft.
Up to 1,700 m of communication range in an open space
Data encryption
Notification of jamming and connection loss
Automatic power adjustment
Effortless installation and maintenance
FireProtect 2 (Heat/Smoke/CO) Jeweller is ready to operate straight out of the box. With no enclosure disassembly required and intuitive in-app setup, it can be up and running within minutes. Maintenance and testing are just as effortless thanks to the self-test feature, real-time device state, and remote configuration available in Ajax apps.
Adding to the system via a QR code
SmartBracket panel with a 90° rotation angle and no enclosure disassembly
Configuration and testing in mobile and desktop Ajax apps
Dustproof and insect-resistant smoke chamber that does not require cleaning
Fallback interconnection is available only for FireProtect 2 Jeweller detectors with firmware version 5.59.2.9 or later.
Technical information
FireProtect 2 RB (Heat/Smoke/CO) Jeweller
FireProtect 2 SB (Heat/Smoke/CO) Jeweller
Ajax product categories
In an Ajax system, you can combine devices of all product categories: Intrusion protection, Video surveillance, Fire and life safety, or Comfort and automation. Create the system to suit your needs and manage it in a single interface.
Fire sensors of the security system
Fire alarm system designed to detect fires, points in the room with high air temperature and smoke. These measures include an alarm system, fire suppression, smoke extraction, shut-off of supply ventilation and air conditioning to stop the spread of fire in the event of an emergency.
What are the components of a fire alarm system
Fire alarm systems include sensors, receiving and control equipment, warning systems, communication channels, backup power supply, special software and other elements.
Fire sensors are divided into four main types:
1) The heat sensor of the fire alarm system reacts to the presence of temperature changes. Heat sensors are divided into:
- a) threshold - with a given limit of a certain temperature level, after which the sensors will be triggered.
- b) integral — respond to a rapid temperature increase. Due to the temperature threshold at which the sensor is activated, which is approximately 70 °C, threshold fire sensors have relatively low efficiency. The low cost of these sensors is the only factor affecting demand. Fires at an early stage can be detected with the help of built-in fire detectors. However, due to the fact that they use two thermocouples, one outside the sensor and the other inside, and the signal processing system is built into the sensor itself, the cost of such fire detectors will be high.
Only when heat is the primary symptom of a fire can heat sensors be used for fire alarms.2) Smoke detectors. Smoke in the air is detected by smoke detectors. The theory of scattering of infrared radiation on smoke particles is the basis of the operation of almost all types of smoke detectors. The disadvantage of such a sensor is that it can work in environments with high levels of steam or dust. Although it is obviously not used in dusty or smoky environments, the smoke detector is used quite often.3) The flame sensor indicates the presence of an open fire or smoldering fireplace. Flame detectors must be installed in places where a fire can start without the prior release of smoke. Because flame detection occurs at an early stage, when conditions such as smoke and a significant increase of temperature are absent, they are more effective than the previous two types of detectors. In addition, in some industrial buildings, which are characterized by high dustiness or significant heat exchange, only fire detectors are used.4) Combined fire alarm sensors combine different fire indication identification methods. Most often, combined sensors combine a heat detector with a smoke detector. This makes it possible to more accurately determine the presence of a fire indication so that an alarm signal can be sent to the remote control. The complexity of the technologies used to create these sensors affects their cost.A correctly constructed fire alarm system, which depends on the information from the fire detector, is directly responsible for the entire effectiveness of the fire extinguishing system. Thanks to this, you can evaluate the effectiveness of the fire protection system of the building as a whole, taking into account the optimal location, the use of the appropriate type of sensor for certain rooms and the quality of fire detectors.In the event of a fire, notification systems for residents, guests, or personnel of buildings and structures contribute to the prompt evacuation of people. Using the Ajax sensor as an example, we will show the principle of operation and features of combined fire sensors.
FireProtect 2 (Heat/Smoke/CO) — a wireless fire detector with smoke, temperature and carbon monoxide sensors
The FireProtect 2 (Heat/Smoke/CO) wireless fire detector is designed for quick fire detection. A dual-spectrum sensor can distinguish between smoke and water vapor. The thermistor quickly reacts to the burning of synthetic materials. The one-of-a-kind smoke chamber does not require frequent cleaning, and simple software reduces false alarms. All this complies with the latest fire safety regulations. The well-thought-out mounting and design of the sensor, as well as the settings via smartphone, ensure easy and quick installation of the fire sensor. A built-in siren for alarm and event notification is included in the fire detector. The FireProtect 2 (Heat/Smoke/CO) wireless fire detector can function both independently and as part of the Ajax security system.
The sensor is available in two versions. Model with replaceable batteries and non-replaceable - RB and SB, respectively.
The principle of operation of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector
Detecting smoke and not ignoring water vapor with the fire detector Ajax FireProtect 2 is possible thanks to a bispectral optical sensor with blue and infrared LEDs. LEDs emit light with different wavelengths. This allows the device to determine the size of the volatile particles and react to the smoke.The smoke chamber of the sensor is protected from external debris and insects. Dust does not threaten detection and does not damage the device, even if it enters and settles in the smoke chamber. Air particles or insects cannot be in two beams at the same time and cause an alarm due to the structure of the optical system.Two built-in thermistors are responsible for the response to the increase in temperature of the wireless fire detector. Thermistors are located outside the sensor for better threat detection. The sensor detects rapid temperature rise and sounds an alarm if the room temperature exceeds 64 °C or rises by 10 °C or more within one minute, even in the absence of smoke. In FireProtect 2 (Heat/Smoke/CO), a built-in chemical sensor with a service life of at least 10 years is responsible for detecting a dangerous concentration of carbon monoxide.Carbon monoxide (CO) is a colorless, tasteless, and odorless gas produced when the fuel in heating engines and vehicle engines that use coal or other natural fuels does not burn completely. For example, it can be created through heating systems, boilers or fireplaces. In closed, sealed rooms with insufficient ventilation, life-threatening concentrations of carbon monoxide can accumulate.The interconnected fire alarm fire alarm function activates the built-in sirens of all Ajax fire detectors in the system if at least one of them has responded to the trigger. This makes it possible to notify as many people as possible inside the building in the event of a fire.
The sirens of all FireProtect 2 (Heat/Smoke/CO) sensors can be activated in 20 seconds thanks to the advanced algorithm of the synchronized alarm.
FireProtect 2 (Heat/Smoke/CO) sensors can be used without connecting to an Ajax control panel. In this case, the sensor notifies of fire alarms with a built-in siren and LED indication, but does not send a notification to the user's smartphone, Ajax Translator or the PRO Desktop application.
Jeweller wireless communication technology
A radio protocol called Jeweller provides fast and reliable two-way communication between connected devices and the hub of the security system. The protocol allows wireless connection of the control panel with FireProtect 2 (Heat/Smoke/CO) at a distance of up to 1700 meters. Even on very large objects, sensors can be installed thanks to such a communication range. In a system with any number of FireProtect 2 (Heat/Smoke/CO), the radio protocol also allows for a synchronized alarm of fire detectors to be triggered in 20 seconds. Thanks to Jeweller, users and the monitoring panel can always view the current status of detectors in Ajax applications.The wireless fire detector Ajax FireProtect 2 (Heat/Smoke/CO) constantly checks the state of the battery and built-in sensors. If a fault is detected, the hub will immediately notify users and the monitoring console. And the sensor will turn on the built-in siren and LEDs for light and sound alarm notification, respectively. In Ajax applications, all sensor states can be checked at any time.The sensor can be tested manually. When you press the front panel of the sensor, it turns on. The mechanical button on the front panel can be pressed both by hand and, for example, with a mop. During the test, the built-in siren is activated, and the sensors are checked. This allows the installation engineer to test the device when necessary and show the customer how the sensor will react to different types of alarms with sound and light.
Autonomous operation of the FireProtect 2 (Heat/Smoke/CO) wireless fire detector
The FireProtect 2 (Heat, Smoke, CO) fire alarm sensor is available in two models with replaceable and fixed power cells. Sensors with replaceable batteries can last up to 7 years with CR123A batteries already installed. Discharged batteries can be replaced with new ones.The permanent battery model uses built-in lithium power cells for at least 10 years of operation. Such a sensor must be replaced with a new one after the batteries are discharged.
Installation and connection of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector
It is not necessary to open the sensor enclosure to install FireProtect 2. Pre-installed replaceable or fixed power supplies are available, and no tools are required to remove the SmartBracket from the sensor. The SmartBracket mounting panel allows you to later align the position of the sensor after installation.In less than a minute, the sensor is connected to the Ajax security system. You need to run the Ajax app, scan the QR code and add the device to the security group and room.